Direct Burial - Aluminum Conductor
Source: King Wire Inc.
Type USE-RHH-RHW-2 building wire and service cable is recognized for use as general purpose wiring at a maximum conductor temperature of 90°C in wet or dry locations for installation in air, conduit or other recognized raceways and for direct burial in circuits not exceeding 600 volts
King Wire Inc.h="480" border="1" cellspacing="0" cellpadding="0" bordercolorlight="#FFFFFF" bordercolordark="#000000">
Part
Number
Description
A4/0-01X00
4/0 STR XLP-USE AL BLACK
King Wire Inc.h="480" border="0" cellspacing="0" cellpadding="0">
King Wire Inc.h="480" border="1" cellspacing="0" cellpadding="0" bordercolorlight="#FFFFFF" bordercolordark="#000000">
AWG
Size
Stranding
Weight
(lbs/1000ft)
4/0
19/w
268
King Wire Inc.h="480" border="0" cellspacing="0" cellpadding="0">
King Wire Inc.h="480" border="1" cellspacing="0" cellpadding="0" bordercolorlight="#FFFFFF" bordercolordark="#000000">
Insul
Thickness (mils)
Outside
Diameter
(inches)
Current
Rating
(Amps)
80
.635
205
@ 90°C
King Wire Inc.h="480" border="0" cellspacing="0" cellpadding="0">
King Wire Inc.h="480" border="0" cellspacing="0" cellpadding="1">
Application
Type USE-RHH-RHW-2 building wire and service cable is recognized for use as general purpose wiring at a maximum conductor temperature of 90°C in wet or dry locations for installation in air, conduit or other recognized raceways and for direct burial in circuits not exceeding 600 volts.
Specifications
UL Standards 44 (RHW or RHH) , UL standard 854 (USE) and Federal specification JC-30B NEC
King Wire Inc.h="480" border="0" cellspacing="0" cellpadding="0">
<%=company%>
(inches)
(Amps)
Type USE-RHH-RHW-2 building wire and service cable is recognized for use as general purpose wiring at a maximum conductor temperature of 90°C in wet or dry locations for installation in air, conduit or other recognized raceways and for direct burial in circuits not exceeding 600 volts.
Construction
Compressed stranded 1350 or compact stranded 8000 Series aluminum
alloy conductor, black abrasion, heat, moisture and sunlight resistant
crosslinked polyethylene insulation.
UL Standards 44 (RHW or RHH) , UL standard 854 (USE) and Federal specification JC-30B NEC
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Packaging: 500 ft reels or master reels
The above data are approximate and subject to normal manufacturing tolerances.
This website uses cookies to ensure you get the best experience on our website. Learn more